frtu

The CS-MDAS-DCU-IO is a telecontrol intended for remote monitoring and control of Medium Voltage switch gear equipments, disconnectors, load break switches and ring main unit in energy distribution networks. The CS-MDAS-DCU- IO consists of one RS232/RS485 port and one 10/100 Ethernet port.The supported protocols are IEC 60870-5-104 for remote connectivity and Modbus-RTU or DLMS/COSEM for energy meter connectivity. The Ethernet port is also used for configuration and diagnostics. The CS-MDAS-DCU-IO is designed for DIN rail mounting and have 19 digital inputs and 12 digital outputs. The unit also provides secure control and reliable control operations via SCBO(Select Check-Before Operate.)

  • 19 Digital Inputs and 12 Digital Outputs
  • Ethernet port for remote SCADA Connectivity
  • RS232/RS485 Port for measuring device
  • Web-based configuration
  • IEC 60870-5-104 protocol for SCADA connectivity
  • Supports multiple master on IEC 60870-5-104
  • Optional Modbus RTU/DLMS COSEM for measuring devices
  • DIN Rail mountable
  • Remote Configuration and Remote firmware upgrade
  • Substation Automation
  • FPI Automation Ÿ Recloser
  • Voltage Regulators
  • Distribution Transformer Monitoring
  • Capacitor Bank Controllers
  • Ring Main Unit
Digital Inputs
  • 19 optically isolated status inputs: 24 VDC or 48VDC with 10% overload
  • 3KV Optical isolation
  • LED indications
  • 4-5 mA typical current burden per input indications
  • Disconnection type terminal block for input
Control Outputs
  • 12 Trip / Close 1 Form B contacts
  • 2 Amp current carrying capability
  • 180 W breaking @ 30 VDC
  • Optioal Select-Before Operate (SBO) functionality The CS-MDAS-DCU- IO consists of one The CS-MDAS-DCU-IO
  • Disconnection type terminal block for input
Communicatons
  • 1 x 10/100 Ethernet port for with IEC 60870-5104 Slave protocol for SCADA Connectivity and local configuration and diagnostic
  • 1 x RS232/RS485 Serial Port with optional Modbus RTU /DLMS COSEM for energy measurement
  • Connectors: RJ45 for Ethernet, RJ45 for Serial port
Configuration
  • Web based configuration
  • Web based configuration
Power Supply
  • Voltage: 20 to 60VDC
  • Maximum of 10 W power
LED Indication
  • 19 status indication for Inputs
  • 12 Status Indication for command outputs
  • Ethernet Link Status and Port Speed
  • Power-on status
  • RS232 communication status
Physical
  • Dimension: 385 mm x 136 mm x 50 mm
  • Metal Enclosure
  • Mounting: DIN Rail
  • IP20 Rating
Environmental
  • Operating Temperature: 0°C to 70°C
  • Humidity : 5% to 95% RH Non-Condensing
Standards and Protection Completed
  • CISPR 22 – Conducted disturbance at main ports
  • EN61000-4-2 – ESD Immunity Test
  • EN61000-4-4 – Electrical fast transient/burst immunity test
  • EN61000-4-5 – Surge immunity test
Under Process
  • IEC 68-2-1 – Cold test
  • IEC 68-2-1 – Dry Heat test
  • IEC 68-2-6 – Vibration test
  • IEC 68-2-30 – Damp heat, cyclic (12+12 hour cycle)
  • EN61000-4-3 – Radiated immunity test
  • CS-MDAS-DCU-IO