CS-RTU1000 is a compact telecontrol unit intended for remote monitoring and control of medium voltage switch gear equipments like disconnectors, load break switches, ring main unit and transformer monitoring in energy distribution networks.

CS-RTU1000 has 8/16 digital inputs, 4/8 digital outputs, 4 channel RTD, in-built 3G/4G modem, Isolated Rs232 / RS485 port (for meter communication) and a 10/100 Ethernet port. Supported protocols are IEC 60870-5104/DNP3.0 for remote monitoring & control operations and MODBUS for energy meter connectivity. The Ethernet port is used for configuration and diagnostics.

Select - before operate control relays issue secure and reliable control operations

CS-RTU1000 is designed for DIN rail mounting.

Related Links Meter Interface Modem
  • 8/16 Digital Inputs and 4/8 Digital Outputs
  • Built-in 3G/4G modem
  • Web-based configuration
  • DIN Rail mountable
  • SIM Sealing provision for Security/Tamper proof
  • Optional Ethernet Port for debug or local connectivity
  • Optional Isolated RS232/RS485 Port for measuring devices
  • Optional protocols like MODBUS RTU for meter connectivity
  • Wireless RTU uses IEC 60870-5-104/DNP3.0 protocol for SCADA connectivity
  • FPI AutomationRecloser
  • Voltage Regulators
  • Distribution Transformer Monitoring
  • Capacitor Bank Controllers
  • Ring Main Unit
  • Street Light Control
Remote Terminal Unit CS-RTU-1000/Automation
Digital Inputs
  • 8 / 16 optically isolated status inputs: 24 VDC or 48VDC with 10% overload
  • LED indications
  • 4-5 mA typical current burden per input indications
  • Disconnection type terminal block for input
Control Outputs
  • 4 / 8 Trip / Close 1 Form B contacts
  • 2 Amp current carrying capability
  • 180 W breaking @ 30 VDC
  • 35 W breaking @ 150 VDC
  • Optional Select-Before Operate (SBO) functionality
  • Disconnection type terminal block for input
Modem - 3G Option
  • Dual band HSPA and dual band GPRS/EDGE
  • Upto 7.2mbps Uplink and 21mbps Downlink speed
Modem - 4G Option
  • LTE-FDD: B1/B3/B5/B8
  • LTE-TDD: B34/B38/B39/B40/B41
Communications
  • Protocols: IEC 60870-5-104/DNP3.0 Slave for SCADA connectivity
  • Protocol available as options Modbus RTU/IEC 60870-5-101 and IEC 60870-5-103
  • 1 x RS232/RS485 Serial Port for Meters (Modbus Master)
  • Optional 10/100 Ethernet port for configuration/local control
  • Built-in 3G/4G Modem for remote connectivity
  • Connections: RJ45 for Ethernet, RJ45 for Serial port
Configuration
  • Web based configuration
Power Supply
  • Input options: 9 to 18VDC or 18 to 36VDC
  • Maximum of 10 W power
Physical
  • Dimension: 153 mm(W) x 115(H) mm x 92(D) mm
  • Metal Enclosure
  • Mounting: DIN Rail
  • Terminations: status input, control output, power, SIM slot, antenna
Environmental
  • Operating Temperature: 0 to 70
  • Humidity : 95% non-consensing at 55
Standards and Protection
  • CISPR11 - Electromagnetic disturbance
  • EN61000-4-2 - ESD Immunity Test
  • EN61000-4-3 - Radiated immunity test
  • EN61000-4-4 - Electrical fast transient/burst test
  • EN61000-4-6 - Conducted immunity test
  • IEC 68-2-1 - Cold test
  • IEC 68-2-1 - Dry Heat test
  • IEC 68-2-6 - Vibration test
  • IEC 68-2-30 - Damp heat, cyclic (12+12 hour cycle)
  • IP20 Rating
Order Options
  • CS-RTU1000-PXYZ
  • P= Digital I/O Option
  • 0 = No I/O
  • 1 = 8 DI/4 DO
  • 2 = 16DI/8 DO
  • X= Power Supply Option
  • 1 = 9 to 18VDC
  • 2 = 18 to 36V DC/li>
  • Y= Analog Card Option
  • 0 = No Analog Card
  • 1 = 4-Channel Analog Card
  • 2 = 4-Channel RTD Card.
  • 3 = 4-Channel Combo card 2 Channel Analog Input and 2-Channel RTD Input
  • Z= Modem Option
  • 0 = No Modem
  • 1 = GPRS(2G) Modem
  • 2 = 3G Modem
  • 3 = 4G Modem