DLMS DCU at best price in Bangalore
DLMS DCU at Best Price in Bangalore: Choose from a vast range of CMSGP products that are available in diverse specifications that meet on client’s demand. DLMS DCU is the global standard for smart energy metering, control, and management. It defines an application layer protocol, an object-oriented data model, and media-specific communication profiles.
DLMS procedure adopted by energy meters is regulated as DLMS. Any AMR/AMI system that obtains data from meters has to understand this procedure or protocol. In technical terms, the intermediate Data concentrator Unit will require DLMS client. For any system integrators and developers, understanding, learning and working on with the DLMS client is a challenge. DL-DLMS gateway is a simple DCU that act as a DLMS client and gives you the data over Modbus. It is an intelligent device that collects data from the meter at pre-defined intervals and gives the upstream system with meter data over Modbus. Looking for DLMS DCU at best price in Bangalore.
DLMS -Data Loss Monitoring System, DLMS DCU at best price in Bangalore
DLMS stand for "Data Loss Monitoring System". It is a set of procedures to be followed by an AMR/AMI system to detect data loss and prevent it from creating any issues. According to the DLMS procedure, data loss monitoring should start when the system starts up and continues during the hours that the system is running. This practice helps in detecting data loss due to power outages or other reasons. It also lets you know if any changes have been made to the AMR/AMI system's configuration or software that might have an impact on the data being captured.
DLMS can also be used to detect unauthorized access to the AMR/AMI system. While this may not be a major concern for most systems, it is still important to have procedures in place for situations where someone might try to get access to your systems without permission. DLMS can also be used as a safeguard against malicious attacks. For example, if unexpected changes are detected, they can be checked against known exploits and vulnerabilities in order to mitigate potential threats.
Related Link:Energy Management Solution Providers India
Compact Wireless Distribution
- Features
- Application
- Specifications
- Upto a maximum of 5 meters per port in RS-485 mode
- Ethernet port supports 10/100Mbps speed
- Triple Isolation for Serial ports
- Ethernet port supports Auto MDI/MDIX
- Data acquired every 5 minutes/ 15 minutes
- Each Serial port supports a maximum of
- Ethernet port supports 10/100Mbps speed
- Stores data up to 45 days for 20 meters
- 5V supply for meter serial port in RS232 mode
- Two Ethernet ports for local and remote data acquisition
- Acquires Load survey, Midnight data, Tamper and Events
- Four Serial ports support both RS232/RS485 Interface
- Each Serial port supports 1 meter in RS232 mode.
- 30 minutes / 60 minutes as per meter integration period
- Serial ports support DLMS/COSEM protocol 15 KV ESD Protection and 2KV surge protection for serial port
- Power supply - 85V AC to 264VAC /120V DC to 370V DC or 20 to 60 V DC

- No. of ports : 2
- Speed : 10Mbps, 100Mbps
- Connector : 8-pin RJ-45 with Built-in indication
- Protection : Built-in 2kV isolation
- Status Indication : Link and Speed
- No. of Ports : 4
- Interface : RS232/RS485
- Connector : 8-pin RJ45
- Data Rate : 9600 bps to 115kbps
- Status Indication : Tx and Rx
- Input : 85 to 264 V AC /120 to 370 V DC or 20 to 60 V DC
- Connector : Disconnection Terminal Block
- Power : 125 mA maximum @ 220V DC
- consumption : 500mA at 24V DC
- Operating Temperature : 0°C to 60°C
- Storage Temperature : -10°C to 85°C
- Operating Humidity : 5 - 95% RH Non-Condensing
- Dimension : 72mm(W) x 151mm(H) x 148mm(D)
- Shock and Vibration : IEC 60068-2-27, 2-6
- EMI/EMC : EN-61000-4-2, 4-4, 4-5, 4-6, 4-8
: EN-55022, CISPR 11 RE, CE - Evironmental : IEC 60068-2-2, 2-3, 2-14
- Saftey : EN61010-1 Dielectric and Insulation Resistance Test
- CS-MDAS-DCU-PS01 : 20 TO 60 V DC
- CS-MDAS-DCU-PS02 : 85 TO 264 V AC/120 TO 370 V DC
- CS-MDAS-DCU-4G-PS01 : 20 TO 60 V DC
- CS-MDAS-DCU-4G-PS02 : 85 TO 264 V AC/120 TO 370 V DC